Temperature transducers for thermocouples
TYPE | LXU-811 | LXU-81X |
Photo | ![]() |
![]() |
Schematic | ![]() |
![]() |
Input | ||
Temperature | B, J, K, N, R, S, T¹ | |
Cold junction compensation | automatic / 0°C | |
OUTPUT | ||
2-wire current loop | 4…20 mA | |
Current output | 0…20 mA / 4…20 mA | |
Voltage output | 0…10 V | |
POWER SUPPLY | ||
From current loop | ![]() |
|
Supply voltage range | 10…30 VDC | 24 VDC (20…30 VDC) |
Power supply current | ≤40 mA | |
OTHER | ||
Basic accuracy | ≤0,1 % | |
Sensor break signalization (max / min) | ![]() ![]() |
![]() ![]() |
Sensor linearization | ![]() |
![]() |
Reversed output | according to the order | |
Galvanic isolation | input / output | |
Galvanic isolation (test) | 1500 VAC | |
Working temperature | 0…70°C | |
Protection (housing / teminals) | IP20 / IP20 | |
Mounting | DIN rail | |
CONFIG | ||
Config | according to the order | |
OPTIONS | ||
One / two-channel | ![]() ![]() |
![]() |
Other input / output ranges (on request) | ![]() |
![]() ![]() |
DOCUMENTS | ||
Data sheet | ![]() |
![]() |
¹or another according to the order |